PCE Instruments – PCE-ND10 Three-Phase Power Analyzer

Quick Info

The 3-phase-power meter / 3-phase power analyzer is able to perform current, voltage and power measurements in 3-phase systems. By using appropriate transducers, it is also possible to measure high currents and voltages with the 3-phase-current meter. The 3-phase-power analyzer was designed for panel-mounting in 92 x 92 mm panel cut-outs.

 

– Power meter for panel-mounting (92 x 92 mm)
– Measurement of U, I, f, P, Q, S, PF…
– Power supply via voltage input
– Alarm function
** Different variants can be selected! Note: This item must be configured before ordering! **

Price

Available on backorder

Description

Description / Highlights

3-Phase-Power Meter / 3-Phase Power Analyzer PCE-ND10 for permanent installation / Lighted 3.5 ” display / 2 alarm outputs / impulse output / Modbus RTU interface / IP 656 front / phase recognition / measurement and display of power, voltage, power rating, efficiency factor, phase angle…

The 3-phase-power meter / 3-phase power analyzer is able to perform current, voltage and power measurements in 3-phase systems. By using appropriate transducers, it is also possible to measure high currents and voltages with the 3-phase-current meter. The 3-phase-power meter was designed for panel-mounting in 92 x 92 mm panel cut-outs. The front of the device is protected against dust and splash water according to IP65.

 The measured values are shown on the large, lighted display of the 3-phase-power meter. Via the Modbus RTU interface, the data can also be transferred. The alarm function of the 3-phase-power meter allows the set up of alarm limits which trigger an alarm signal, when the value exeeds or falls below the threshold. The settings can be adjusted by using the buttons on the front of the 3-phase-power meter.

– Power meter for panel-mounting (92 x 92 mm)
– Measurement of U, I, f, P, Q, S, PF…
– Power supply via voltage input
– Alarm function
– Recognition of false phase order
– Pulse output of active energy
– IP 65 protected front
– lighted 3.5″ LC display
– Simple installation
– RS485 Modbus interface

Specification

Technical specifications
current In
1 A Display range: 0.00 … 1500 A
Measuring range: 0.005 … 1.2 A AC
Accuracy: ±0.2 % of measuring range
5 A Display range: 0.00 … 60000 A
Measuring range: 0.025 … 6 A AC
Accuracy: ±0.2 % of measuring range
Voltage L-N
230 V Display range: 0.0 … 1.012 MV
Measuring range: 195 … 253 V AC
Accuracy: ±0.2 % of measured value
290 V Display range: 0.0 … 1.200 MV
Measuring range: 246 … 300 V AC
Accuracy: ±0.2 % of measured value
Voltage L-L
400 V Display range: 0.0 … 1.752 MV
Measuring range: 340 … 440 V
Accuracy: ±0.5 % of measured value
500 V Display range: 0.0 … 2.000 MV
Measuring range: 425 … 520 V
Accuracy: ±0.5 % of measured value
Frequency Display range: 47.0 … 63.0 Hz MV
Measuring range: 47.0 … 63.0 Hz
Accuracy: ±0.2 % of measured value
Active power Display range: -9999 … 9999 MW
Measuring range: -1.52 … 1.52 kW
Accuracy: ±0.5 % of measuring range
Reactive power Display range: -9999 … 9999 Mvar
Measuring range: -1.52 … 1.52 Mvar
Accuracy: ±0.5 % of measuring range
Apparent power Display range: 0.00 VA … 9999 MVA
Measuring range: 1.0 VA … 1.52 VA
Accuracy: ±0.5 % of measuring range
Power factor PF Display range: -1 … 1
Measuring range: -1 … 1
Accuracy: ±1 % of measuring range
Tan φ Display range: -1.2 … 1.2
Measuring range: -1.2 … 1.2
Accuracy: ±1 % of measuring range
Cos φ Display range: -1 … 1
Measuring range: -1 … 1
Accuracy: ±1 % of measuring range
φ Display range: -180 … 180 °
Measuring range: -180 … 180 °
Accuracy: ±0.5 % of measuring range
Absorbed active energy Display range: 0 … 99,999,999 kWh
Accuracy: ±0.5 % of measuring range
Released active energy Display range: 0 … 99,999,999 kWh
Accuracy: ±0.5 % of measuring range
Absorbed reactive energy Display range: 0 … 99,999,999 kWh
Accuracy: ±0.5 % of measuring range
Released reactive energy Display range: 0 … 99,999,999 kWh
Accuracy: ±0.5 % of measuring range
THD Display range: 0 … 100 %
Accuracy: ±5 % of measuring range
General technical specifications
Relay output 2 outputs
max. 250 V AC / 0.5 A
Impulse output active power O/C (NPN)
class A according to EN62053-31
voltage 18 … 27 V
current 10 … 27 mA
RS485 interface Modbus RTU 8N2 / 8E1 / 8O1 / 8N1
Baud rate 4800 / 9600 / 19200 / 38400 bit/s
Display monochrome 3.5″ LCD, lighted
Supply voltage from L3 195 … 253 V AC / 47 … 62 Hz
246 … 300 V AC / 47 … 62 Hz
Operating conditions -20 … 55 °C / 25 … 95 % RH
Storage conditions -30 … 70 °C / non-condensing
Electrical safety EN 61010-1
Dimensions 96 x 96 x 77 mm
Panel cut-out 92 x 92 mm
Weight ~ 300 g
Protection class IP65

1x 3-phase-power meter PCE-ND10, 2 x connection clamps, 1x instruction manual

Delivery Scope

1 x 3-Phase-Power Meter / 3-Phase Power Analyzer PCE-ND10
2 x connection terminals
1 x operating manual

Downloads

datasheet-pce-nd10.pdf
Datasheet

Add On

Additel 673 Advanced Digital Pressure Calibrators
Additel 673 Advanced Digital Pressure Calibrators

Additel 686 Advanced Digital Pressure Gauges
Additel 686 Advanced Digital Pressure Gauges

Additel 685 Digital Pressure Gauges
Additel 685 Digital Pressure Gauges

Additel 273Ex Handheld Pressure Calibrator
Additel 273Ex Handheld Pressure Calibrator