PCE Instruments – PCE-PA 8300-1

Quick Info

The easy-to-use 3-Phase Power Meter / 3-Phase Power Analyzer is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. This is a 3-phase power analyzer that features:

– Voltage measurement range of 10 V … 600 V AC
– Current measurement range of (Set 1) 20 A … 1200 A AC
– Performance measurement range of 0 kW … 9.999 MW (VA/VAR)
– Simultaneous display of harmonics and waveform
– Graphic Phasor diagram
– Captures transients including dip, swell, and outage

Price

Available on backorder

Description

Description / Highlights

PCE-PA 8300 3-Phase Power Meter / 3-Phase Power Analyzer
3-phase / 3 current clamps / LCD graphic display / SD card memory

The PCE-PA 8300 is a 3-Phase Power Meter / 3-Phase Power Analyzer that features a durable enclosure, SD card memory, a LCD graphic display, as well as apparent, effective, and reactive power measurement. The easy-to-use PCE-PA 8300 3-Phase Power Meter is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity.

Set 1: Includes 3 current clamps for measurements up to 1200 A AC

– Voltage measurement range of 10 V … 600 V AC
– Current measurement range of 20 A … 1200 A AC (Set 1)
– Performance measurement range of 0 kW … 9.999 MW (VA/VAR)
– Simultaneous display of harmonics and waveform
– Graphic Phasor diagram
– Captures transients including dip, swell, and outage
– SD card memory
– LCD graphic display
– Durable enclosure
– Compatibility with various manufacturers’ power clamps
– Adjustable back-up interval, allowing for long-term data collection
– Auto-setting of measurement range (AC V)
– Power efficiency, delay angle, and frequency measurement
– Apparent, effective, and reactive power measurement
– Harmonic spectrum measurement up to the 50th order

Specification

Electrical specifications
Voltage Measurement (AC V)
Measurement Range Resolution Accuracy
10 V … 600 V (phase to neutral) 0.1 V ±(0.5 % + 0.5 V)
10 V … 600 V (phase to phase 0.1 V ±(0.5 % + 0.5 V)
Current Measurement (AC A) Set 1
Measurement Range Resolution Accuracy
20 A 0.001 A (< 10 A)
0.01 A (≥ 10 A)
± (0.5 % + 0.1 A)
200 A 0.01 A (< 100 A)
0.1 A (≥ 100 A)
± (0.5 % + 0.5 A)
1200 A 0.1 A (< 1000 A)
1 A (≥ 1000 A)
± (0.5 A + 5 A)
Effective power
Measurement range Resolution Accuracy
0 KW … 9.999 KW 0.001 KW ±(1 % + 0.008 KW)
10 KW … 99.99 KW 0.01 KW ±(1 % + 0.08 KW)
100 KW … 999.9 KW 0.1 KW ±(1 % + 0.8 KW)
1 MW … 9.999 MW 0.001 MW ±(1 % + 0.008 MW)
Apparent Power
Measurement range Resolution Accuracy
0 KVA … 9.999 KVA 0.001 KVA ±(1 % + 0.008 KVA)
10 KVA … 99.99 KVA 0.01 KVA ±(1 % + 0.08 KVA)
100 KVA … 999.9 KVA 0.1 KVA ±(1 % + 0.8 KVA)
1 MVA … 9.999 MVA 0.001 MVA ±(1 % + 0.008 MVA)
Reactive Power
Measurement range Resolution Accuracy
0 KVAR … 9.999 KVAR 0.001 KVAR ±(1 % + 0.008 KVAR)
10 KVAR … 99.99 KVAR 0.01 KVAR ±(1 % + 0.08 KVAR)
100 KVAR … 999.9 KVAR 0.1 KVAR ±(1 % + 0.8 KVAR)
1 MVAR … 9.999 MVAR 0.001 MVAR ±(1 % + 0.008 MVAR)
Active Energy
Measurement range Resolution Accuracy
0 KWH … 9.999 KWH 0.001 KWh ±(2 % + 0.008 KWh)
10.00 KWH … 99.99 KWH 0.01 KWh ±(2 % + 0.08 KWh)
100.0 KWH … 999.9 KWH 0.01 KWh ±(2 % + 0.8 KWh)
1 MWH … 9.999 MWH 0.001 MMh ±(2 % + 0.008 MWh)
Apparent Energy
Measurement range Resolution Accuracy
0 KVARH … 9.999 KVARH 0.001 KVARh ± (2 % + 0.008 KVARh)
10.00 KVARH … 99.99 KVARH 0.01 KVARh ± (2 % + 0.08 KVARh)
100.0 KVARH … 999.9 KVARH 0.01 KVARh ± (2 % + 0.8 KVARh)
1 MVARH … 9.999 MVARH 0.001 MVARh ± (2 % + 0.008 MVARh)
Power Factor
Measurement range Resolution Accuracy
0 … 1 0.01 ± 0.04
Delay Angle
Measurement range Resolution Accuracy
-180° … +180° 0.1° ±1°
Frequency
Measurement range Resolution Accuracy
45 Hz … 65 Hz 0.1 Hz ± 0.1 Hz
Harmonic of AC Voltage at 50 / 60 Hz
Measurement range Resolution Accuracy
1 … 20th order 0.001 … 1 A
0.1 %
± (2 % + 0.5 A)
± (2 % + 10 Digit)
21 … 30th order 0.001 … 1 A
0.1 %
± (2 % + 0.5 A)
± (2 % + 10 Digit)
21 … 50th order 0.001 … 1 A
0.1 %
not specified
General specifications
Display 3.7 in / 94.0 mm point-matrix LCD (320 * 240 pixel) with LED background lights
Safety standards IEC1010CAT III 600V
Input resistance AC V 10 MOhm
Operating frequency of current clamp 40 Hz … 1 kHz
Tested operating frequency of current clamp 45 Hz … 65 Hz
Overload protection AC V
AC A
720 V RMS
1300 A with current clamp
Data Storage SD memory card
Refresh interval 1 second
Data logging function logging with real-time speed on SD memory card
Record interval 2 … 7200 seconds
Data output (only for live display on computer) per USB or RS232, depending on connection cable
Operating temperature 0° C … +50° C / 32° F … 122° F
Surrounding humidity < 80 % RH
8 x 1.5 V AA batteries
Voltage Supply 9 V adapter
Current Drain Measurement Device: 300 mA DC
current clamp: 34 mA DC
Maximum Wire Diameter 50 mm / 1.9 in
Weight Measurement Device: 948 g / 33.4 oz (incl. battery)
Current clamp: 467 g / 16.4 oz (incl. cable)
Dimensions Device: 225 mm x 125 mm x 64 mm / 8.8 in x 4.9 in x 2.5 in
Current clamp: 210 mm x 64 mm x 33 mm / 8.2 in x 2.5 in x 1.2 in
Clamp jaw: 86 mm / 3.3 in (exterior)

Delivery Scope

1 x PCE-PA 8300 3-Phase Power Meter / 3-Phase Power Analyzer
3 x Current clamps (Set 1)
4 x Insulated alligator clips
4 x Safety test lines
6 x 1.5 V AA batteries
1 x 9 V mains adapter
1 x SD memory card
1 x Carrying case
1 x User manual

Downloads

manual-3-phase-power-meter-pce-pa-8300.pdf
Manual

datasheet-3-phase-power-meter-pce-pa-8300.pdf
Datasheet

Add On

Additel 673 Advanced Digital Pressure Calibrators
Additel 673 Advanced Digital Pressure Calibrators

Additel 686 Advanced Digital Pressure Gauges
Additel 686 Advanced Digital Pressure Gauges

Additel 685 Digital Pressure Gauges
Additel 685 Digital Pressure Gauges

Additel 273Ex Handheld Pressure Calibrator
Additel 273Ex Handheld Pressure Calibrator